High-throughput screening of protein surface activity via flow injection analysis-pH gradient-dynamic surface tension detection

TitleHigh-throughput screening of protein surface activity via flow injection analysis-pH gradient-dynamic surface tension detection
Publication TypeJournal Article
Year of Publication2005
AuthorsStaggemeier, BA, Bramanti, E, Allegrini, C, Skogerboe, KJ, Synovec, RE
JournalAnalytical Chemistry
Volume77
Pagination250–258
ISSN00032700 (ISSN)
Keywordsair, Article, Calibration, concentration (parameters), data analysis, dynamic surface tension detector, Dynamic surface tension detectors, elution, Flow injection analysis, Flow injection analysis (FIA), Food Analysis, Kinetics, Liquid, pH, pH effects, pH gradients, pressure, protein, protein analysis, Proteins, Reaction injection molding, Real time systems, reproducibility, Screening, sensor, serum albumin, solvent, steady state, Surface tension, thermodynamics, Throughput
Abstract

Using flow injection analysis (FIA), a pH gradient is blended in real time with a protein sample as the pH-dependent protein surface activity is measured by a dynamic surface tension detector (FIA-pH-DSTD). This instrumental system was developed as a high-throughput method for the screening of protein surface activity at the air/liquid interface as a function of pH. This method utilizes the continuous flow, drop-based dynamic surface tension detector in combination with flow injection sample introduction and blending of a steady-state concentration of protein sample with a pH gradient ranging from pH 2.0 to pH 11.5. Dynamic surface tension is measured through the differential pressure across the air/liquid interface of repeatedly growing and detaching drops. Continuous surface tension measurement is achieved for each eluting drop of 2-s length (2 $μ$L), providing insight into both the kinetic and thermodynamic behaviors of molecular orientation processes at the liquid/air interface. Three-dimensional data are obtained, with surface tension first converted to surface pressure, which is collected as a function of elution time versus drop time. In FIA-pH-DSTD, a commercial pH probe is used to measure pH during elution time, enabling surface pressure throughout drop time to be subsequently plotted as a function of eluting pH. An automated DSTD calibration procedure and data analysis method is applied, which allows simultaneous use of two different solvents, permitting real-time dynamic surface tension data to be obtained. The method was applied to the analysis of 14 commercial purified proteins, yielding characteristic features of surface activity as a function of pH. The reproducibility of the measurement and selectivity advantage of the DSTD was shown for the analysis of serum albumins from various mammalian sources. Several applications were also suggested and discussed in order to show the potential of the method for protein and food chemistry studies and in the study of protein-polymer interactions.

URLhttp://www.scopus.com/inward/record.url?eid=2-s2.0-11844249940&partnerID=40&md5=0b51fdc87273bf10ec18d6f0f0623f7c
DOI10.1021/ac049088f